Fuse Links (Products)

Medium-voltage fuse links

Products

Range of medium-voltage fuses

CNC LTD fuses are designed for transformer and electrical equipment protection, ensuring safe and fast short-circuit interruption.

7.2 kV fuses

Product code Rated voltage
(kV)
Rated current
(A)
Rated breaking capacity
(kA)
Minimum breaking current
(A)
Power dissipation
(W)
Cold resistance
(mΩ)
Length
(mm)
Pre-arcing I²t
(A²s)
Total I²t
(A²s)
Tubular diameter
(mm)
Weight
(kg)
E(P)A/B-7,2-2,53/7,22,55084,58801921071531,1
E(P)A/B-7,2-43/7,2450157,242119227200531,1
E(P)A/B-7,2-6,33/7,26,350249,418719253420531,1
E(P)A/B-7,2-103/7,210503918,71241922571920531,1
E(P)A/B-7,2-163/7,216506320,9521923392950531,1
E(P)A/B-7,2-203/7,220507620,2261928276200531,1
E(P)A/B-7,2-253/7,225509821241929636880531,1
E(P)A/B-7,2-31,53/7,231,55012524,617,3192178512600531,1
E(P)A/B-7,2-403/7,240501503213,8192344922600531,1
EM(P)A/B-7,2-503/7,2505019039,79,7192675939130751,4
EM(P)A/B-7,2-633/7,2635024340,95,41921110568500751,4
EM(P)A/B-7,2-803/7,2805031645419222800152000751,4
EM(P)A/B-7,2-1003/7,212050395653,819228878263000852,4
EM(P)A/B-7,2-1253/7,212550595823,319248253308000852,4

Dimensions

Fuse dimensions (2.5 A–40 A) with 45 mm contact.
Order example: EPA-7.2-25 (with striker)
EA-7.2-25 (without striker)

Fuse dimensions (2.5 A–40 A) with 56 mm contact.
Order example: EPB-7.2-25 (with striker)
EB-7.2-25 (without striker)

Fuse dimensions (50 A–80 A) with 45 mm contact.
Order example: EMPA-7.2-80 (with striker)
EMA-7.2-80 (without striker)

Fuse dimensions (50 A–80 A) with 56 mm contact.
Order example: EMPB-7.2-80 (with striker)
EMB-7.2-80 (without striker)

Fuse dimensions (100 A–125 A) with 45 mm contact.
Order example: EMPA-7.2-100 (with striker)
EMA-7.2-100 (without striker)

Fuse dimensions (100 A–125 A) with 56 mm contact.
Order example: EMPB-7,2-100 (with striker)
EMB-7,2-100 (without striker)

12 kV fuses

Product code Rated voltage
(kV)
Rated current
(A)
Rated breaking capacity
(kA)
Minimum breaking current
(A)
Power dissipation
(W)
Cold resistance
(mΩ)
Length
(mm)
Pre-arcing I²t
(A²s)
Total I²t
(A²s)
Tubular diameter
(mm)
Weight
(kg)
F(P)A/B-12-2,56/122,5508811432921071531,6
F(P)A/B-12-46/124501511,471529227200531,6
F(P)A/B-12-6,36/126,3502416,931529253420531,6
F(P)A/B-12-106/1210503934,1902922571920531,6
F(P)A/B-12-166/1216506320,5422923392950531,6
F(P)A/B-12-206/1220507655,6292928276200531,6
F(P)A/B-12-256/1225509843282929636880531,6
F(P)A/B-12-31,56/1231,5501255828292178512600531,6
F(P)A/B-12-406/1240501505828292344922600531,6
FM(P)A/B-12-506/1250501906820292675939130752,1
FM(P)A/B-12-636/1263502438411,72921110568500752,1
FM(P)A/B-12-806/1280503161099,229222800152000752,1
FM(P)A/B-12-1006/12100503951097,229228878263000853,7
FM(P)A/B-12-1256/12125505951516,129248253308000853,7

Dimensions

Fuse dimensions (2.5 A–40 A) with 45 mm contact.
Order example: FPA-12-25 (with striker)
FA-12-25 (without striker)

Fuse dimensions (2.5 A–40 A) with 56 mm contact.
Order example: FPB-12-25 (with striker)
FB-12-25 (without striker)

Fuse dimensions (50 A–80 A) with 45 mm contact.
Order example: FMPA-12-80 (with striker)
FMA-12-80 (without striker)

Fuse dimensions (50 A–80 A) with 56 mm contact.
Order example: FMPB-12-80 (with striker)
FMB-12-80 (without striker)

Fuse dimensions (100 A–125 A) with 45 mm contact.
Order example: FMPA-12-100 (with striker)
FMA-12-100 (without striker)

Fuse dimensions (100 A–125 A) with 56 mm contact.
Order example: FMPB-12-100 (with striker)
FMB-12-100 (without striker)

24 kV fuses

Product code Rated voltage
(kV)
Rated current
(A)
Rated breaking capacity
(kA)
Minimum breaking current
(A)
Power dissipation
(W)
Cold resistance
(mΩ)
Length
(mm)
Pre-arcing I²t
(A²s)
Total I²t
(A²s)
Tubular diameter
(mm)
Weight
(kg)
F(P)A/B-24-2,510/242,55081826804421071532,5
F(P)A/B-24-410/244501527143044227200532,5
F(P)A/B-24-6,310/246,350242961344253420532,5
F(P)A/B-24-1010/24105039511544422571920532,5
F(P)A/B-24-1610/24165063103424423392950532,5
F(P)A/B-24-2010/24205076103334428276200532,5
F(P)A/B-24-2510/2425509870334429636880532,5
F(P)A/B-24-31,510/2431,5501258030442178512600532,5
F(P)A/B-24-4010/24405015010328442344922600532,5
FM(P)A/B-24-5010/24505019013221442675939130753,8
FM(P)A/B-24-6310/246350243178124421110568500753,8
FM(P)A/B-24-8010/248050316171944222800152000753,8
FM(P)A/B-24-10010/24100503952401344228878263000855,7
FM(P)A/B-24-12510/24125505953181144248253308000855,7

Dimensions

Fuse dimensions (2.5 A–40 A) with 45 mm contact.
Order example: FPA-24-25 (with striker)
FA-24-25 (without striker)

Fuse dimensions (2.5 A–40 A) with 56 mm contact.
Order example: FPB-24-25 (with striker)
FB-24-25 (without striker)

Fuse dimensions (50 A–80 A) with 45 mm contact.
Order example: FMPA-24-80 (with striker)
FMA-24-80 (without striker)

Fuse dimensions (50 A–80 A) with 56 mm contact.
Order example: FMPB-24-80 (with striker)
FMB-24-80 (without striker)

Fuse dimensions (100 A–125 A) with 45 mm contact.
Order example: FMPA-24-100 (with striker)
FMA-24-100 (without striker)

Fuse dimensions (100 A–125 A) with 56 mm contact.
Order example: FMPB-24-100 (with striker)
FMB-24-100 (without striker)

36 kV fuses

Product code Rated voltage
(kV)
Rated current
(A)
Rated breaking capacity
(kA)
Minimum breaking current
(A)
Power dissipation
(W)
Cold resistance
(mΩ)
Length
(mm)
Pre-arcing I²t
(A²s)
Total I²t
(A²s)
Tubular diameter
(mm)
Weight
(kg)
E(P)A/B-36-2,520/362,52082244135371071533,7
E(P)A/B-36-420/364201547219953727200533,7
E(P)A/B-36-6,320/366,3202552102953753420533,7
E(P)A/B-36-1020/36102039685875372571920533,7
E(P)A/B-36-1620/36162063991825374802840533,7
E(P)A/B-36-2020/36202095991725375803460533,7
E(P)A/B-36-2520/3625201101111165379636880533,7
E(P)A/B-36-31,520/3631,52015013587537178512630533,7
E(P)A/B-36-4020/36402018014069537344922620533,7

Dimensions

Fuse dimensions (2.5 A–40 A) with 45 mm contact.
Order example: EPA-36-25 (with striker)
EA-36-25 (without striker)

Fuse dimensions (2.5 A–40 A) with 56 mm contact.
Order example: EPB-36-25 (with striker)
EB-36-25 (without striker)